Groundwater treatment plant for the purification of PFC and BTEX
Treated media: Soil, Groundwater, Air
Flow rate: 8 m3/h
Substances: BTEX, VOC, MOH, PAH, PFC
Processes: Biological treatment, Gravel filtration, Pump and Treat
Commissioning: 2021
KF Company: Harbauer Berlin GmbH
The water purification system cleans the BTEX pollutants biologically with the help of a 35m3 bioreactor (suspended matter fluidized bed process). Iron and manganese are cleaned via a filtration stage (two gravel filters) and a separate manganese filter at the end of the plant.
The PFCs are removed from the groundwater via a large three-stage activated carbon filter system with a contact time of almost 6 hours.
The purified water is again infiltrated into several wells and made available for automatic backwashing.